Resistance Tester

Professional Resistance Tester Manufacturer

 

Wuhan HUAYI Electric Power Technology Co., Ltd is a professional manufacturer in China, researching and manufacturing cable fault locator. HUAYI insists on developing and marketing independently, and make efforts to improve the products' quality, reduce cost, and improve efficiency. Widely used in electricity, water conservancy, petroleum, railway, mining, chemical industry and other industries.

 
First 12 Last 1/2
 
Why Choose Us

Rich Experience

The company was established in 2005 and has more than ten years of professional experience. It is one of the earliest manufacturers of high-voltage testers in China. Our products are involved AC/DC Hipot tester, series resonant test system, transformer tester, relay tester, circuit breaker/switch tester, oil/SF6 tester, cable tester and other electric instruments.

Professional Technology Support

Specialize in testing and solutions for more than 18 years. Own experienced engineers. Professional on delivery, installation, debugging, and training.

 

 

 

ISO Certification

We have a professional R&D technical team and strict quality control to ensure safety, accuracy and efficiency. Passed ISO9001 certification and obtained relevant patent certificates.

24 hours After-sales

Professional after-sales service, paying attention to customers' feedback about products; Providing solutions within 24 hours, if the customers have any problem; Act quickly and efficiently.

 

Types of Resistance Tester
10KV Insulation Resistance Tester
Three Phase Contact Resistance Tester
20A DC Resistance Tester
20A 3-phase Transformer Winding Resistance Tester

Grounding Resistance Tester
HYCZ-H Grounding Resistance Tester can auto-test a lot of portable short-circuit ground wire, and personal protective grounding wire under the new safety regulatory requirements, and automatically determine whether the ground wire is qualified.

 

Ground Grid Earth Resistance Tester
Ground grid earthing tester is a kind of high-precision testing instrument used in substations and other fields to test earth resistance and related parameters.

 

High Voltage Insulation Resistance Tester
The instrument combines the advantages of analog circuits, digital circuits, and mechanical operation, and has achieved the leading position in the output voltage, output current, measuring range, measuring accuracy, and anti-interference ability.

 

Clamp On Ground Resistance Tester
The double-clamp multi-function ground resistance tester is specially designed and manufactured for on-site measurement in accordance with the new lightning protection ground resistance detection standard.

 

Pointer Insulation Resistance Meter
The insulation resistance meter (pointer type) itself has the characteristics of large capacity, strong anti-interference ability, diversified measurement indicators, accurate measurement results, simple and rapid measurement process, easy to carry and so on.

 

Water Cooling Generator Insulation Tester
This product is specially used for measuring and testing of water-cooled generator, and can also be used for insulation testing in laboratory or on site.

 

Product Parameter

 

Rated(kV)

0.25,0.5,1,2.5,5,10,15(kV)

Test voltage(kV)

Rated voltage ×(1±10%)The load resistance is not less than 1% of the range

The max error is 10%

RDG range

(0.001~50)GW/5kV/10kV/15kV

(0.001~50)GW/2.5kV

(0.001~50)GW/1kV

(0.001~5)GW/0.5kV

(0.001~5)GW/0.25kV

The max error is 20%RDG range

(50~2000)GW/5kV/10kV/15kV

(50~200)GW/2.5kV

(50~100)GW/1kV

(5~10)GW/0.5kV

(5~10)GW/0.25kV

No requirements

>10T

Output short circuit current

≥5mA

Cx

0.01-9.99uF 20%±5rgd

Absorption ratio, polarization index

Measuring range o

Test range: 0.01 ~9999.99

Error: ±(1%RDG+1d)

Error of output voltage display

±(3%RDG + 1d)

Live monitoring

Alarm AC 0-3KV(re)

 

 
Advantages of Resistance Tester
 
01/

Identify Potentially Hazardous Equipment: One of the primary benefits of using a resistance tester is that it can help identify potentially hazardous equipment. The tester can detect faults in equipment, such as a breakdown in insulation, that may lead to electrical shocks or even electrical fires.

02/

Ensure Reliable Equipment Operation: In addition to safety benefits, a resistance tester can also help ensure reliable equipment operation. This can help prevent costly repairs and outages, and ensure that equipment operates at peak performance.

03/

Easy to Use and Accurate: Resistance testers are designed to be easy to use and provide accurate readings. They typically come with easy-to-read displays and are equipped with features that make them simple to operate.

04/

Efficient Storage: It supports PI and DAR calculations, customizable test modes, and real-time monitoring of voltage, current, and temperature, ensuring safety and reliability. Built-in storage for up to 1,000 data sets, with USB and Bluetooth connectivity for easy data export.

 

Application of Resistance Tester
 

Power industry
Resistance tester is widely used in the power industry in power generation, transmission, and distribution processes. Electrical equipment, such as generators, transformers, switchgear, etc., require insulation resistance testing to ensure safe operation.

 

Communication industry
From communication base stations to data centres, resistance testers detect the insulation performance of communication equipment, ensuring its normal operation in high-voltage environments.

 

Transportation industry
Resistance testers are crucial for ensuring traffic safety in the transportation industry, especially in the railway and air transportation industries. The power supply equipment of the railway system and the electrical system of the aviation system both require resistance testing.

 

Manufacturing
From automation equipment on production lines to maintenance of factory lighting systems, resistance testers can help manufacturing enterprises promptly identify potential insulation problems and ensure the safe operation of equipment.

 

Construction industry
Electrical equipment and power systems are indispensable and important components in the construction industry. Resistance testers are widely used in construction sites to ensure the safety of electrical equipment.

 

Petrochemical industry
Resistance testers are of great significance in this industry to ensure the safety and stability of equipment. Conducting insulation resistance tests on petrochemical equipment can identify potential insulation faults promptly to avoid production accidents and environmental pollution caused by insulation issues.

 

Differences Between Ground Resistance Tester and Insulation Resistance Tester

Different uses

The insulation resistance tester is used to test the size of the insulation resistance between two conductors, and the grounding and resistance tester is used to measure the contact resistance between the grounded electrode (plate) buried in the ground and the earth.

The resistance value is different

The insulation resistance tester is usually measured by a large resistance value, such as more than 1 megaohms, grounding, resistance tester is measured by the resistance value is usually small, such as below 20 ohms.

Different test methods

The test method of the grounding and resistance tester is that the electrical equipment relies on the ground to connect to the same potential, which is the tightness of the contact between the wire or lightning protection lead line and the earth, and the insulation resistance tester is not.

 

Usage Requirements
 

Safety Operations

Avoid unauthorized modifications to the tester's circuits or parameters to prevent safety incidents.

Compliance with Safety Regulations

Before use, inspect the electrical connections of the tester, such as the power source and plugs, ensuring there are no issues such as burrs or fractures.

Appropriate Selection of Testing Conditions

Select different testing conditions based on the characteristics of the test object, such as test current and test duration.

Prevention of High Voltage Breakdown

During testing, insulation between the tester's electrodes and the device to be tested is necessary to avoid high-voltage breakdown incidents.

Maintenance Attention

Regular maintenance and timely replacement of parts, along with circuit inspections, are necessary to extend the tester's lifespan.

Environmental Considerations

During usage, consider the environmental factors such as humidity, temperature, and atmospheric pollution, as these can impact the accuracy of test results.

 

How To Cooperate With Us

 

Please contact us with any questions about products, services, or technology issues. We will always be with you and listen to your needs.

Our address

Gaoxin 4th Road, No.40, Wuhan city, China

Phone Number

(+86)-18062012971/whatsapp:+8618064115448

E-mail

Sales@sinohipot.com/ tina@sinohipot.com

 

Packaging and Delivery

 

Packing detail:

Packing with wooden cases, provide different solutions of shipping way.

Payment:

We accept many payment term, such as T/T, Western Union, L/C.

Warranty period:

One-year warranty, Installation, and commissioning of specific products.

Delivery time:

Most of our products are in stock and can be delivered upon payment. The delivery time usually does not exceed 15 days.

 

productcate-1-1

productcate-1-1

 

Our Certificates

 

 

productcate-1-1

 

FAQ

Q: How can I place an order?

A: You can contact us online or sending us an inquiry. Please provide the details of your requirements as clear as possible. So we can send you the offer at the first time.

Q: When can I get the price?

A: Usually we quote within 24 hours after we get your inquiry.

Q: What is your minimum order quantity, can you send me samples?

A: Our minimum order quantity is 1 set, and the sample shipping fee needs to be provided by you.

Q: Do you have the products in stock

A: Most Of our tester has stock.You can contact us to make sure

Q: Is there the products tested before shipping?

A: Our products undergo factory testing and are accompanied by reports.

Q: Would you have a discount?

A: Yes we could offer different discount according to your order quantity. We also hold regular promotional activities every year.

Q: Have your products been exported?

A: We have more than 10 years of export experience. Please contact us to confirm if there is a local partner.

Q: What about the transportation?

A: Usually we take door to door express delivery ,cause it's more convenient and fast.

Q: What is the difference between an insulation resistance tester and a megohmmeter?

A: An insulation resistance tester and a megohmmeter are tools used to measure electrical resistance, but they differ in their specific use. An insulation resistance tester is used to verify the effectiveness of electrical insulation in wire or devices, while a megohmmeter specifically measures high resistance or insulation resistance, typically in millions of ohms.

Q: How do you test insulation resistance?

A: Insulation resistance is tested using an resistance tester, also known as a megohmmeter. This device applies a direct current (DC) voltage across the insulator and measures the resulting leakage current, which is then used to calculate the insulation’s resistance. This process helps identify potential issues like moisture, contamination, or physical damage.

Q: How does a resistance tester work?

A: A resistance tester, often a digital multimeter (DMM), measures resistance by applying a known current or voltage and then measuring the resulting voltage drop or current flow, respectively. This is based on Ohm's Law, which states that resistance (R) equals voltage (V) divided by current (I) (R = V/I).

Q: What affects insulation resistance tester readings?

A: Remember that the measured resistance (of the insulation) will be determined by the voltage applied and the resultant current (R = e/I). There are a number of things that affect current, including temperature of the insulation and humidity, as mentioned in the previous section.

Q: What is the difference between a continuity test and a resistance test?

A: Continuity testing is commonly used to check fuses, trace wires, check for short and open circuits etc. Resistance readings are necessary for identifying motor terminals, checking for a breakdown in insulation and checking thermistors.

Q: What to disconnect when doing an resistance tester?

A: Prior to carrying out an insulation resistance test, any equipment likely to influence the test results obtained, or be damaged by the test voltage, such as surge protective devices, dimmers, electronic switches and high frequency luminaires, should be disconnected.

As one of the most professional resistance tester manufacturers and suppliers in China, we're featured by quality products and competitive price. Please rest assured to buy cheap resistance tester made in China here from our factory.

dc voltmeter, HV divider, vlf equipment