ExploreTroubleshooting Transformer Oil BDV Test ResultsOct 30, 2026The breakdown voltage of insulating oil is one of the most sensitive indicators of oil condition and of the internal health of a transformer. Because
-
What level of PD requires action, and how does this become Condition-Based Maintenance?Oct 30, 2026At what measured value should I stop trending and start planning an outage? There is no universal pass/fail figure, because apparent charge depends on
-
How do I separate real PD from electrical noiseOct 29, 2026The plant is full of drives, welding sets and radio traffic. How can I be sure the pulses I see come from the motor? Noise rejection is the core field
-
How do I interpret a PRPD pattern from a stator winding of motor?Oct 29, 2026My instrument produces a phase-resolved discharge plot. What features distinguish the common defect types? PRPD (Phase-Resolved Partial Discharge) plo
-
What are the available PD sensors for motors and generators, and what are their installation cons...Oct 29, 2026Sensor choice is driven by the frequency range of the discharge, the noise environment and whether the machine can be opened. HFCT (High-Frequency Cur
-
Should partial discharge be measured online or offline for moto?Oct 29, 2026What is the practical difference between an offline and an online partial discharge test on a motor, and which one should I specify? They answer two d
-
Why is the very-low frequency has more advantages than DC testing?Oct 29, 2026DC testing is not obsolete everywhere. It remains a valid method for paper-insulated lead-covered (PILC) cable, for some generator and motor insulatio
-
VLF vs. DC Hipot Comparison TableOct 29, 2026The table below summarises the four decisive differences between the two methods, followed by the test-parameter differences that follow from them.
-
VLF vs. DC Hipot TestingOct 29, 2026FAQ 1: Why is DC Hipot testing considered a "hidden danger" for XLPE cables? Answer: The primary danger is Space Charge accumulation . Under
-
How to Test Transformer Turns RatioOct 16, 2026Why Test Transformer Turns Ratio? The turns ratio test (TTR test) is one of the most fundamental and revealing diagnostic measurements performed on a
-
Substation Equipment Testing & Commissioning: Technical FAQOct 14, 2026FAQ 1: What is the difference between "Pre-commissioning Tests" and "Service Tests" in a substation? Answer: Pre-commissioning Tes
-
MV Cable Triple Diagnostics: Frequently Asked QuestionsOct 10, 2026FAQ 1 Q: What is the "Triple Diagnostic" approach for MV cables, and why is a single test not enough? Answer: Medium voltage (MV) distribution cables-