Zeroing In: Practical Techniques for Underground Cable Fault LocationJul 29, 2026In the world of high-voltage maintenance, few tasks are as high-pressure as locating a fault in an underground cable. Every hour of downtime translate
-
The Future of Green Grids: Why Advanced SF6 Recovery is the New Standard for GIS MaintenanceJul 28, 2026In the global transition towards sustainable energy, the power industry faces a unique challenge: balancing the unmatched insulation performance of Ga
-
Why Series Resonance is Mandatory for HV Cable TestingJul 21, 2026In the world of high-voltage (HV) commissioning, long-distance XLPE cables are often referred to as "Capacitance Monsters." As power grids m
-
If a flashover happens inside the GIS during the test, will the basin insulator be permanently ru...Jul 16, 2026Series resonance protection is very important for GIS insulators. Once a flashover occurs, the capacitance changes abruptly, and the resonance conditi
-
GIS is fully enclosed. Where is the best place to inject the test voltage?Jul 16, 2026Although SF6 gas inside GIS has excellent insulating properties, it is highly sensitive to residual metal particles. Applying the series resonant syst
-
Why must we repeat this dangerous test on-site after installation?Jul 15, 2026The manufacturer has already tested the GIS at 100% voltage in a clean factory environment. Why must we repeat this dangerous test on-site after insta
-
Why can't I just use a regular high-voltage test transformer to test a 220kV GIS?Jul 15, 2026It is a matter of Physics and Power. A GIS busbar is essentially a massive, high-voltage coaxial capacitor. The Problem: In AC systems, a capacitor re
-
Explore the knowledge about Burden of CT PT meansurementJul 14, 2026For Maintenance & Protection Engineers, there are very useful FAQ about Secondary Burden & 10% Error Curve Analysis. Through them, we can lear
-
Explore the knowledge about CT PT meansurementJul 10, 2026During the transformer testing process, as a power engineer, we may encounter various problems during the operation. Through the following questions a
-
How do we choose the test voltage for an on-site test?Jul 08, 2026Q: My GIS is rated for 220 kV. Should I test it at the same voltage the factory used during their Type Test? A: NO. Field test voltages are lower to a
-
Why PD monitoring is MANDATORY during AC Hipot?Jul 06, 2026Q: If we are doing a withstand test, why also monitor partial discharge? A: Hipot is a "Pass/Fail" test; PD is a "Diagnostic" test
-
UHF vs. Ultrasonic (AE) — Which is better for GIS testing?Jul 03, 2026Q: Some engineers use acoustic devices, others use UHF monitors. Which is superior? A: They are partners, not competitors. UHF is for scanning electro