Today, we will introduce the working principle of Huayi DC High Voltage Generator.
1. Connect the chassis and the voltage doubler to the appropriate position, connect the power cable, the cable and the grounding cable, and protect the grounding cable and the working connection;
2. Check whether the instrument, discharge rod, pressure doubler, test product connecting wire, and grounding wire are correct, whether the grounding wire connection is reliable, and check whether the high-voltage safety distance meets the requirements, before starting the high-voltage test of the test product;
3. The over-voltage protection setting value is usually 1.1 times of the test voltage;
4. Stably adjust the pressure potentiometer in a clockwise direction. After the output is boosted from zero, after boosting the required voltage, record the reading of the ammeter according to the specified time, and check the control box and the high-voltage output line for abnormalities and sounds, and proceed on the test piece. Leakage and DC withstand voltage test;
5. After checking and testing to confirm that there is no abnormality in the tester, start the test sample, leakage and DC withstand voltage test;
6. For large capacitance testing, it is necessary to monitor that the charging current of the ammeter does not exceed the large charging current of the tester;
7. It is suitable for small capacitor samples, such as zinc oxide surge arresters, magnetic lightning arresters, etc.;
8. Increase the voltage to 95% of the required value, and then slowly increase it to the required voltage (current). Then read the current value of the voltage from the digital display.
9. Press color button, the voltage will be reduced to 75%, and keep this state. At this time, the current measurement value can be read.