Product Introduction

 

Measuring dielectric Loss is a basic method in insulation tests, which can effectively find the deterioration damp of insulators on electrical equipment as well as local defects. It is widely used in electrical manufacturing, electrical equipment installation, handover, and preventive tests. It is the most basic way to evaluate the insulation of electric equipment by measuring the dielectric losses of its transformers, instrument transformers, reactors, capacitors, bushing, and arresters.

 

Product Parameter

 

Work condition

-15℃∽40℃

RH<80%

Principle of anti-interference

Variable frequency

Power supply

AC 220V±10%

Permissible generator

 

 

Output high voltage

0.5KV∽10KV(can make 12kV)

Every each 0.1kV

Accuracy

2%

Max current

200mA

Capacitance

2000VA

 

self-excitation power supply

 

AC 0V∽50V/15A

50HZ,60HZ single frequency,45HZ/55HZ,47.5HZ/52.5HZ,55HZ/65HZ,57.5HZ/62.5HZ,Automatic double frequency conversion

resolution

tgδ: 0.001%

Cx: 0.001pF

 

Accuracy

△tgδ:±(reading*1.0%+0.040%)

△C x :±(reading*1.0%+1.00PF)

 

 

 

 

Test range

tgδ

No limitation

 

C x

15pF < Cx < 300nF

10KV

Cx < 60 nF

5KV

Cx < 150 nF

1KV

Cx < 300 nF

CVT test

Cx < 300 nF

LCR test range

L>20H(2kV)

R>10KΩ(2kV)

LCR test accuracy

1%

angular resolution

0.01

CVT turn ratio range

10∽10000

CVT turn ratio accuracy

1%

CVT turn ratio resolution

0.01

size(host)(mm)

350(L)×270(W)×270(H)

size(accessory)(mm)

350(L)×270(W)×160(H)

Memory capacity

200 group Support U disk data storage

weight(host)

22.75Kg

weight(accessory)

5.25Kg

 

Model 

 

JS-H

JS-V

JS-R

UST mode

GST mode

CVT self-excitation mode

C1/C2 test simultaneously

 

External standard voltage

 

External high voltage

 

CVT turn ratio

 

CVT test

UST/GST test simultaneously

 

LCR auto test

 

Insulation resistance test

 

 

USB connection

 

U disk storage

 

 

Product Feature And Application

 

1. Big touched screen LCD display: easy to use and no need to train the user, only click the screen to finish the whole test process

2. High storage capacity: can save 200 group data, results can be saved in chronological order, historical records can be viewed at any time, and can be printed out;

3. data management: The instrument data can be exported through a U disk, and can be viewed and managed on any PC.

4. Multiple test modes: It can test by internal high voltage, external high voltage, internal standard, external standard, positive connection method, reverse connection method, self-excitation method, and other methods; High voltage (> 10kV) dielectric loss can be made under the condition of external standard external high voltage.

5. CVT test:can test CVT(capacitor voltage transformer)C1/C2 of dielectric loss and capacitance,can test C1/C2 simultaneously. Can also test CVT Variation ratio and voltage Angle difference;

6. no need to remove the high voltage cable to test CVT: can test CVT dielectric loss and capacitance with no need to remove HV cable

7. CVT Reverse connection shielding measuring C0: can test the dielectric loss value and capacitance value of CVT upper C0

8. high-speed sampling signal: The inverter and sampling circuit inside the instrument are all controlled digitally, and the output voltage is continuously adjustable.

9. LCR full auto test: Automatic display inductance, capacitance, resistance measurement, Angle.

10. multiple protection features: such as input voltage fluctuation, high voltage current, output short circuit, power supply fault, overvoltage, overcurrent and temperature, etc., to ensure the safety and reliability of the instrument. also equipped with a grounding detection function to ensure that the ungrounded equipment does not allow voltage boost.

 

Prodection Details
6
accessory
6
accessory
4
Panel
JS-H tan delta tester
tester

 

Accessory

 

Serial Number

Name

Amount

1

Inter-frequency dielectric loss tester

one

2

High voltage cable

one

3

Low voltage cable

two

4

Power line

one

5

Ground lead

one

6

CVT Line

one

7

5A Fuse (Internal)

two

8

Printing paper (50ml)

one

9

Specification

one

10

Inspection Report

one

11

Certification

one

 

FAQ

 

1. Delivery: Fast delivery and Flexible mode of transportation
2. Payment: Choose payment terms and payment way you convenient
3. Sale service: 24-hour online contact, Choose the right model of equipment according to your request, give the best offer, support customization
4. Warranty period: All machine quality guarantees for one year and lifetime technical support for you. Online response to customers' technical problems.

 

Customer Visit

 

product-1280-720

On Site Service

 

product-1200-600

Packing detail

product-1142-517

Our service

01

Pre-sale service

Conduct product consultation, product promotion, and marketing activities, and technical support for customer needs.

02

Delivery service

Packing with wooden cases, provide different solutions of shipping way, accept different payment way. Save shipping cost and make sure the products arrive well.

03

After-sales service

Installation and commissioning of specific products; Respond to consumer questions, answer consumer inquiries, and deal with consumer comments.

modular-1

Hot Tags: transformer dissipation factor test set, China transformer dissipation factor test set manufacturers, suppliers, factory, Transformer Tan Delta Tester, Tan Delta Tester, dga testing, Transformer Dissipation Factor Test Set, hipot wire vlf testing

Send Inquiry