80KV 100KV Oil BDV Tester Single Cup

80KV 100KV Oil BDV Tester Single Cup

Model number: JYY-HI
1. Complies IEC standard and many standards, and can also set customized parameters.
2.Automatic test and easy to operate.
3.Updated software and high performance.
Product Introduction

 

JYY-HI Oil BDV Tester

It is our company's all scientific and technical personnel, according to the relevant provisions of national standard GB507-1986 and line standard DL/T846.7-2004, exert their advantages, after many field tests and long-term unremitting efforts, carefully developed high high-accuracy, full-digital industrial instrument. In order to meet the needs of different users, the series of instruments can be divided into single cup, three cups, and multiple cups. The instrument is easy to operate and beautiful in shape. Due to the use of automatic digital microcomputer control, the measurement is of high precision, has strong anti-interference ability, and is safe and reliable.

 

Product Parameter

 

1. Capacity of booster 1.5kVA
2. Boost speed of 0.5kV/s-5.0kV/s (increasing every 0.5), 10 grades optional. Difference of 0.2 kV/s by mistake
3. Output voltage 0 ~ 80 kV (optional)
4. Voltage accuracy (2% reading +2 words)
5. Power distortion rate < 1%
6. Electrode clearance standard 2.5mm
7. Test times: 6 times (1-10 times optional)
8. Resting time 900S(0-5900s optional)
9. Interval rest time 300S(0-5900s optional)
10. Stirring time 15S (0-250s optional)
11. Display mode: Large LCD Chinese characters display
12. The port 232 communication port is standard.
13. Overall dimension length 430 mm; 350 mm wide; 370 mm high
14. The weight of the instrument is 36 kg

 

Conditions of use

1. Ambient temperature 0-40 ° C

2. Relative humidity ≤ 85%

3. Power supply AC 220V ± 20%

4. Power frequency 50 Hz ± 5 Hz

5. Power consumption < 200 W

 

Product Feature And Application

 

1. The instrument is controlled by a large-capacity single-chip microcomputer, and the work is stable and reliable.

2. A wide range watchdog circuit in the instrument to eliminate the phenomenon of a crash;

3. A variety of operation options, the instrument program with GB507-1986, GB507-2002, two national standard methods, industry-standard DL/429, international standard IEC60156, and custom operation, can adapt to a variety of choices of different users;

4. The oil cup of the instrument is molded by special glass at one time to prevent the occurrence of oil leakage and other interference phenomena.

5. The unique high voltage sampling design of the instrument allows the test value to be directly input into the A/D converter, avoiding the error caused in the analog circuit, so that the measurement results are more accurate.

6. The instrument has overcurrent, over-voltage, short circuit protection, and other functions, and has a strong anti-interference ability, good electromagnetic compatibility.

7. Portable structure, easy to move, indoor and outdoor use are very convenient.

 

Production Line

 product-315-376product-425-245

FAQ

 

Q1: What is the difference between IEC 60156 and ASTM D1816, and which method should we follow?

Answer:

The two standards differ in electrode geometry, gap, stirring and voltage application, and therefore produce different numbers from the same oil. IEC 60156 uses spherical electrodes with a 2.5 mm gap, a motor-driven voltage rise and no forced stirring between breakdowns, which suits mineral insulating oils in European and most Asian specifications. ASTM D1816 uses VDE electrodes with a 1 mm or 2 mm gap, gentle stirring and a specified rest period, and is the usual reference in North American practice.

Follow the method named in the purchase specification, the asset owner's maintenance procedure, or the national grid code for the territory. Never compare a result obtained under IEC 60156 with a limit written for ASTM D1816, or the reverse - a 40kV reading can be acceptable under one method and marginal under the other. The practical solution is a tester that stores both procedures as selectable presets, so the method, gap and electrode type travel with every recorded result.

Q2: Why do 60kV, 80kV and 100kV testers exist - does a higher voltage range give a better measurement?

Answer:

The voltage class of the tester defines the ceiling of what it can measure, not the quality of the measurement. New oil and oil from high-voltage assets can break down well above 70kV in the 2.5 mm gap, and a 60kV set simply cannot resolve those values: the test either stops short or the operator is forced to reduce the gap, which invalidates comparison with the standard. A 100kV set clears the range needed for acceptance testing of new oil and for 220kV and above assets, while 60kV and 80kV sets cover the in-service population of distribution and medium-voltage transformers.

Choose the range from the highest value you expect to see, then add margin for the voltage rise during the Ramp Rate and for repeated breakdowns at altitude or in cold weather. Buying a set that sits at its limit produces truncated results and stresses the internal transformer continuously; buying far above the need adds weight and cost without improving accuracy. The selection table on the following page maps each range to its application.

Q3: How does Ramp Rate affect the measured breakdown voltage, and what should be set?

Answer:

The Ramp Rate is the speed at which the test voltage rises across the gap. A slow rise gives the oil time for impurities to migrate and align with the field, so breakdown occurs at a lower voltage; a fast rise can overshoot the true inception value because the trip circuit reacts after breakdown has already started. Both standards fix the rate for exactly this reason, typically around 2 kV per second, and the tester must hold that rate independent of load and mains fluctuation.

Set the rate from the selected standard and leave it there for the whole series. Where a variable rate is offered, use it only for investigative work - for example, a deliberately slow rise when studying particle behaviour - and record the rate alongside the result. Inconsistency between two laboratories testing the same oil is more often a difference in Ramp Rate than a difference in the oil.

 

About Us

 

 

 

Wuhan Huayi Electric Power Technology Co., Ltd

 

HUAYI is a professional manufacturer in China that researches and manufactures electric testing equipment. Established in 2005, the company is one of the earliest manufacturers of high-voltage testers in China. HUAYI insists on developing and marketing its products independently and makes efforts to improve product quality, reduce costs, and enhance efficiency.
HUAYI is committed to preventative, maintenance, troubleshooting, and commissioning. With ISO-certified professional engineering support and Satisfactory customer service, our brand has been recognized and supported by a wide range of users.

 
01
 

large enterprise scale

Efficient and precise processing and testing equipment. We have our factory, engineers, and service team.

 
02
 

Standardized Production

Passed ISO9001 certification and obtained relevant patent certificates.

 
03
 

High-Quality Customized Services

No intermediate links, providing one-stop service from design, processing, mold trial to mass production.

company

 

 

Our certification

 

Certificates -2

 

 

Our engineering team

 

test onsite

 

Customers visiting

 

customer visit

 

Our workshop

 

factory

Our Service

Create a comprehensive solution for customers

01

Pre-sale service

Conduct product consultation, product promotion, and marketing activities, and provide technical support for customer needs.

02

Delivery service

Packing with wooden cases, provide different solutions of shipping way, accept different payment way. Save shipping cost and make sure the products arrive well.

03

After-sales service

Installation and commissioning of specific products; Respond to consumer questions, answer consumer inquiries, and deal with consumer comments.

packing
 

FAQ

 

1. Delivery: Fast delivery and Flexible mode of transportation
2. Payment: Choose payment terms and a convenient payment method
3. Sales service: 24-hour online contact, choose the right model of equipment according to your request, give the best offer, support customization
4. Warranty period: All machine quality guarantees for one year, and lifetime technical support for you. Online response to customers' technical problems.

 

How To Cooperate With Us?

Please get in touch with us if you have any questions about products, prices, technology solutions, or services. We will always be with you.

Our address

Gaoxin 4th Road, No.40, Wuhan City, China

Phone Number

(86)-18062012971/+8618064115448 WhatsApp

E-mail

sales@sinohipot.com/ tina@sinohipot.com

HUAYI
220KV GIS 2
One-stop high voltage test equipment Factory in China

 Send your inquiry about test equipment to us and experience the professional solutions it can have on your business or brand. With our technology solutions and products, you can elevate your products, captivate your customers, and unlock new opportunities for growth and success in the electric industy.

Hot Tags: 80KV 100KV Oil BDV Tester Single Cup, China 80KV 100KV Oil BDV Tester Single Cup manufacturers, suppliers, factory, breakdown voltage test of transformer oil, transformer oil breakdown voltage, oil dielectric strength test, bdv tester, bdv oil test, oil breakdown tester

Send Inquiry