Oil Chromatography Test Set
video
Oil Chromatography Test Set

Oil Chromatography Test Set

Transformer oil chromatograph is used to determine the component content of dissolved gas in transformer oil by chromatography. It is an effective means for power generation and power supply enterprises to determine whether there is latent overheating, discharge and other faults in oil-filled power equipment in operation.
Product Introduction

 

YSP-H Gas chromatography is a separation and analysis technology of multicomponent mixtures. It mainly uses the differences of boiling point, polarity, and adsorption coefficient of each component in the sample in the chromatographic column, so that each component can be separated in the chromatographic column, and qualitative and quantitative analysis of the separated components.

 

The gas chromatography takes the gas as the flow phase (carrying gas), When the sample is fed into the sample inlet and vaporized, it is carried by carrier gas into the packed column or capillary column, due to the difference of boiling point, polarity and adsorption coefficient of each component in the sample, so that each component is separated in the column Then, according to the physicochemical characteristics of the components, the detector son-in-line will be detected in order, and finally through serial or network data transmission to the chromatography workstation, by the chromatography workstation will be each component of the gas chromatography record and analysis to obtain the analysis of each component of the analysis.

 

Transformer oil chromatograph is used to determine the component content of dissolved gas in transformer oil by chromatography. It is an effective means for power generation and power supply enterprises to determine whether there is latent overheating, discharge and other faults in oil-filled power equipment in operation.

 

The total analysis of seven gas components dissolved in insulating oil can be completed by one injection(H2, CH4, C2H2, C2H4, C2H6, CO, CO2), if necessary can do full analysis of nine components (H2, O2, N2, CH4, C2H2, C2H4, C2H6, CO, CO2). The minimum detection concentration of acetylene reached 0.05ppm, and the stabilization time was less than 40 minutes.

 

Product Parameter

 

Network anti-control system

Internal CAN's way, with interface board design, It can be converted to network port output at will

Signal output bits

24-bit

Communication interface

Network interface output(class 6 network cable connections)

Circuit design

ARM embedded design for easy wireless control, remote control and mobile app control

Temperature control system

Six-way independent temperature control

Temperature control

Room temperature - 450 ℃, liquid nitrogen refrigeration: - 80 ℃ - 450 ℃

Column box temperature control accuracy

-0.02℃

Program heating up

Stage 13, 0.1 ℃ / stage

Show module

Large-screen LCD

Display accuracy

0.01 ℃

Lift rate of column and box

0-80 ℃ / min (adjustment increment 0.1 ℃ / min) up to 120 ℃ / min

Temperatu reprogrammed repeatability

≤1%

TCD Detector Sensitivity

S value ≥ 10000mv.ml/mg (benzene) )up to 12000 mv.ml/mg (benzene)

Baseline noise

≤ 8uv

Baseline Drift

≤20uv/30min

Detection limit of FID detector

≤3 x 10-12g/s(thanan)

Baseline noise

≤2 x 10-13A

Baseline Drift

≤5 x 10-13A

Detection limit of ECD detector

≤3 x 10-14g/s(r-666)

Baseline noise

≤1 x 10-13A

Baseline Drift

≤5 x 10-13A

Detection limit of FPD detector

≤2 x 10-11 g/s(Sulfur in methyl parathion)

Baseline noise

≤2 x 10-13A

Baseline Drift

≤4 x 10-13A

Extended

≤6 external events can be added

Automation engineering

Can be increased: automatic ignition function, automatic sampler connection, four-way flow pressure display function, optional counter-control workstation to achieve counter-control

 

Product Feature And Application

 

  1. Adopted the state-of-the-art 10/100M adaptive Ethernet communication interface, and built-in IP protocol stack, so that the instrument can easily through the internal local area network, the Internet to achieve long-distance data transmission;It is convenient to set up the laboratory, simplify the configuration of the laboratory and manage the analysis data;
  2. Instrument Internal Design 3 independent connection process, can be connected to the local processing (laboratory site), unit supervisor (e.g. quality inspection section chief, production director, etc.), as well as superior supervisor (e.g. environmental protection bureau, technical supervision bureau, etc.), can easily make the unit supervisor and supervisor real-time monitoring of the operation of the instrument and analysis of data results;
  3. The instrument is equipped with a network version of the workstation that can support multiple chromatography work (253),253 data processing and counter-control, simplified document management, and the maximum degree of reduction of the user's laboratory investment and operating costs;
  4. Instruments can be connected to the manufacturer through the Internet connection, remote diagnostics, remote program updates, etc. (User license );
  5. The instrument can be equipped with a 5.7-inch color LCD screen or color touch screen to meet the needs of different users;
  6. The system has two sets of operating systems, Chinese and English, which can be switched freely;
  7. Temperature control area, electronic flow controller(EFC), and electronic pressure controller(EPC)can be freely named by the user, convenient for user use (optional);
  8. Instruments operate in parallel with a multiprocessor to make the instrument more reliable, to meet complex sample analysis, and to choose from a variety of high-performance detector options such as FID,TCD,ECD,FPD and NPD, with up to four detectors installed simultaneously. Can also use the detector appendage method, the afterthe purchase of the instrument is very convenient to choose and install other detectors,
  9. Instrument using a modular structure design, design clear, easy to replace and upgrade, to protect the effectiveness of investment;
  10. The new microcomputer temperature control system, high-temperature control accuracy, reliability and anti-jamming performance, with six completely independent temperature control systems, can achieve sixteen-order program heating, so that the equipment can be competent for a wider range of sample analysis, with column box automatic rear door system, so that low-temperature control accuracy is improved, rise / cooling faster;
  11. The instrument with and advanced electronic flow controller (EFC)and electronic pressure controller(EPC)to achieve digital control, can greatly improve the reproducibility of qualitative and quantitative results;
  12.  Instrument design timing self-start procedure can easily complete the online analysis of gas samples (Required with online automatic sample components);
  13. The operating system of the full microcomputer control keyboard is simple and convenient to operate, and the detector automatic identification technology, with fault diagnosis and power loss data protection functions, can automatically remember the set parameters;
  14. The color spectrum machine has built-in low noise, high-resolution 24-bit AD circuit, and has the ability to store baselines and baseline deductions.
  15. It is suitable for WinXP, WIN2000, windows 7 and other operating systems. The sampling data is read in by CDF file conforming to a / a (American Analytical Society) standard, so it can be connected with chromatogram workstations such as Agilent and Waters.
  16. With full independent intellectual property rights, and Modbus / TCP standard interface, it can be easily connected with DCS.
  17. The instrument can be connected with the automatic injector produced by many manufacturers at home and abroad, such as aoc-20i of Shimadzu, HT series high-efficiency gas-phase liquid automatic injector of Italy HTA company, etc;

 

Accessory

 

Serial Number

Name

Amount

Serial Number

Name

Amount

1

Quantitative clamp

one

14

Output signal line

two

2

Polyethylene gas pipe

thirty meters

15

Nipper pliers

one

3

Gas injector

one

16

Screwdriver

one

4

Pneumatic nut

one

17

Small screwdriver

one

5

Gas circuit gasket

twenty

18

Wrench (12*14)

two

6

Graphite pad Φ3.1

eight

19

Wrench (8*10)

one

7

Graphite pad Φ5.1

four

20

Screw (M3*6)

ten

8

Injector seal

thirty

21

Flat (Φ3)

ten

9

Gas path

three

22

Copper mesh (Φ3)

one

10

Gas tee

four

23

Combined grounding wire

one

11

Column nut

four

24

Specification

one

12

Fuse (2A, 8A)

six

25

Inspection Report

one

13

Fuse plate

two

26

Certification

one

 

Prodect Qualification
Business license

 

 

 

 

 

 

Business License

Calibration Certificate

Calibration Certificate

ISO 2005

ISO

Patent

Patent

FAQ

 

1. Delivery: Fast delivery and Flexible mode of transportation
2. Payment: Choose payment terms and payment way you convenient
3. Sale service: 24-hour online contact, Choose the right model of equipment according to your request, give the best offer, support customization
4. Warranty period: All machine quality guarantees for one year and lifetime technical support for you. Online response to customers' technical problems.

Customer Visit

 

product-1280-720

On Site Service

 

product-1200-600

Packing detail

product-1142-517

Our service

01

Pre-sale service

Conduct product consultation, product promotion, and marketing activities, and technical support for customer needs.

02

Delivery service

Packing with wooden cases, provide different solutions of shipping way, accept different payment way. Save shipping cost and make sure the products arrive well.

03

After-sales service

Installation and commissioning of specific products; Respond to consumer questions, answer consumer inquiries, and deal with consumer comments.

modular-1

Hot Tags: oil chromatography test set, China oil chromatography test set manufacturers, suppliers, factory, dissolved gas analysis, transformer dissolved gas analysis, furan testing of transformer oil, dissolved gas analysis of transformer oil

Send Inquiry