Product Introduction
HYLH-P SF6 gas recovery and vacuuming service car introduction
The device is suitable for sulfur hexafluoride gas recovery, purification treatment, and gas recharge of power supply bureaus, power plants, substations, high-voltage switch manufacturers, electrical equipment research institutes, and power engineering companies, especially for on-site installation and maintenance of 110KV ~ 550KV GIS switches.
Product Parameter
|
Model |
HYLH-P SF6 gas recovery and vacuuming service car |
|
|
Temperature of Working Circumstances |
-10℃~40℃ |
|
|
Recovery |
Final Pressure(Pa) |
≤500 |
|
Initial Pressure(Pa) |
≤133 |
|
|
Charge |
Final Pressure(KPa) |
0.7 |
|
Charge speed (h/m3 ) |
≤0.2 |
|
|
Vacuum speed(h/m3 ) |
≤0.1 |
|
|
Limit Vacuum (Pa) |
≤10 |
|
|
Vacuum Preservation(Pa/24 hours) |
≤400 |
|
|
Annual Leak Rate |
≤0.5% |
|
|
Purity of the Recovered SF6 Gas |
Moisture Content (PPM/V) |
≤60 |
|
Oil Content (PPM/G) |
≤10 |
|
|
Storage Container |
Mode of Storage |
Liquid State |
|
Pressure (MPa) |
5.0 |
|
|
Volume (L) |
200 |
|
|
Stored Liquid Gas (kg) |
200 |
|
|
Mode of Liquefying |
Liquefaction by refrigeration |
|
|
Regeneration Mode of the Filter of Drying |
Vacuum heating |
|
|
Power Supply |
3Φ 380V 50HZ |
|
|
Total Power Consumption (kW) |
≤20 |
|
|
Noise dB(A) |
≤70 |
|
|
Weight of the device |
About 700 kilograms |
|
|
External dimensions(mm) |
1800*1050*1800 |
|
|
compressor |
Theoretical Discharge |
m3/h |
18 |
|
Vacuum compressor |
Theoretical Discharge |
m3/h |
20 |
|
Limit Vacuum |
pa |
≤500 |
|
|
Vacuum pump |
Speed |
m3/h |
63 |
|
Limit Vacuum |
Pa |
10 |
|
|
Classification |
The second storge |
||
|
Designed Pressure |
MPa |
5.0 |
|
|
Container |
Designed Temperature |
℃ |
100 |
|
Volume |
L |
200 |
|
|
Liquid Storage Capacity of the Container |
kg |
200 |
Product Feature And Application
HYLH-P Mobile SF6 Gas Recovery & Vacuum Refilling Unit
1. Comprehensive Functionality: This all-in-one mobile station integrates vacuuming, ultimate vacuum measurement, SF6 gas recovery, liquefaction, purification, refilling, storage, bottling, and gas transfer capabilities.
2. Advanced Recovery System: Centered around a high-pressure SF6 compressor, the system utilizes a high-efficiency air-cooled design. Both intake and outlet ports are equipped with automated protection-including pressure reducers and solenoid valves-to safeguard the compressor against overpressure and vacuum stress.
3. High-Performance Vacuum System: Features a direct-drive rotary vane vacuum pump, offering a compact, oil-free, and leak-proof design with an ultimate vacuum of 10 Pa. An integrated oil backflow preventer protects switchgear during sudden power losses. Precision digital gauges ensure accurate, real-time monitoring of vacuum levels for equipment and filter activation.
4. Dual-Stage Purification: Equipped with premium high-precision dust, desiccant, and decomposition product filters. The system ensures filtration accuracy down to 1 micron and reduces moisture content to below 40 PPM. Integrated vacuum-heating regeneration technology allows the filters to be reactivated without disassembly, significantly extending service intervals.
5. Precision Refilling & Vaporization: Supports both pressure balance and compression refilling methods to suit various field conditions. The built-in vaporization unit ensures complete gasification during external refilling and optimizes liquid injection efficiency for storage cylinders.
6. Integrated Electrical Controls: Built with top-tier components, the control system provides comprehensive protection against phase reversal, leakage, phase loss, and thermal overloading. A multi-level linkage circuit prevents damage from operational errors, while a customized 500V phase sequence relay enhances system reliability.
7. Multi-Layer Safety Architecture: Featuring triple-redundant pressure protection and explosion-proof safeguards, the unit includes dedicated safety grounding bolts for operator protection. The enclosed cabinet design isolates internal machinery, providing superior dustproofing, waterproofing, and noise reduction.
8. Industrial-Grade Piping: The entire internal circuit is constructed from high-quality copper piping (minimum wall thickness 1.6mm). Precision-routed with horizontal and vertical alignments, all joints use silver brazing (brazing-filling) rather than simple bending, ensuring a high-strength, leak-free, and long-lasting pipeline.
9. Certified Storage System: Every storage tank is individually numbered and certified by national safety authorities. Each tank features a dedicated pressure gauge, relief valve, and backlit liquid level indicator. The level gauge includes clear safety and limit scales to prevent hazardous overfilling.



Accessory
|
Serial Number |
Name |
Amount |
|
1 |
Mainframe |
one |
|
2 |
Test line |
one |
|
3 |
Power |
one |
|
4 |
Specification |
one |
|
5 |
Inspection Report |
one |
|
6 |
Certification |
one |
FAQ
Q1: We already recovered the gas. Why spend hours vacuuming to such a low level?
A: Vacuuming is about removing the "Catalysts of Destruction" - Oxygen and Moisture.
The Hidden Danger:
• Residual Oxygen: Reacts with SF6 under arcs to form toxic SOF2.
• Moisture: The "Enabler" that turns by-products into Hydrofluoric Acid (HF).
Q2: Can we just vent a small amount of dirty gas to speed up the repair?
A: NO. This is a massive environmental and legal violation. SF6 is the worst greenhouse gas known.
The Carbon Balance:
• 1 kg of SF6 = 23,900 kg of CO2.
• Venting one standard cylinder (40kg) = 1.5 Million km driven by a car.
Q3: Is old gas with SO2 safe to reuse?
A: Yes, if your Recovery Unit has a built-in purification system. It works like a "Mini-Refinery."
Purification Sequence:
❶ Oil Filtering: Removes compressor oil and particles.
❷ Molecular Sieves: Absorbs moisture down to < 10 ppm.
❸ Acid Neutralization: Activated alumina filters remove HF and SO2.
Q4: Pressure rose from 10 Pa to 50 Pa in 10 minutes. Is there a leak?
A: Distinguish between a Structural Leak and Surface Outgassing.
Diagnostic Logics:
• Scenario A (Leak): Pressure rises LINEARLY to atmosphere. Fix O-rings.
• Scenario B (Outgassing): Pressure rises then PLATEAUS. Moisture is evaporating.
• Scenario C (Wet System): Rise is too fast to level off. Continue pumping.
On Site Service

Packing detail

Our service
01
Pre-sale service
Conduct product consultation, product promotion, and marketing activities, and technical support for customer needs.
02
Delivery service
Packing with wooden cases, provide different solutions of shipping way, accept different payment way. Save shipping cost and make sure the products arrive well.
03
After-sales service
Installation and commissioning of specific products; Respond to consumer questions, answer consumer inquiries, and deal with consumer comments.

Our certificates

Customers visit

About us
Wuhan Huayi Electric Power Technology Co.,Ltd
HUAYI is a professional manufacturer in China that researches and manufactures electric testing equipment. Established in 2005, the company is one of the earliest manufacturers of high-voltage testers in China. HUAYI insists on developing and marketing independently and makes efforts to improve the products' quality, reduce cost, and improve efficiency.
HUAYI is committed to preventative, maintenance, troubleshooting, and commissioning. With ISO certificated, professional engineering support, and Satisfactory customer service, our brand has been recognized and supported by wide users.
large enterprise scale
Efficient and precise processing and testing equipment. We have our factory, engineers, and service team.
Standardized Production
Passed ISO9001 certification and obtained relevant patent certificates.
High-Quality Customized Services
No intermediate links, providing one-stop service from design, processing, mold trial to mass production.

Please contact us if you have any questions about products, prices, technology solutions, or services. We always be with you.
Our address
Gaoxin 4th Road, No.40, Wuhan city, China
Phone Number
(86)-18062012971/+8618064115448 WhatsApp
sales@sinohipot.com/ tina@sinohipot.com


One-stop high voltage test equipment Factory in China
Send your inquiry about test equipment to us and experience the professional solutions it can have on your business or brand. With our technology solutions and products, you can elevate your products, captivate your customers, and unlock new opportunities for growth and success in the electric industy.
Hot Tags: SF6 Gas Recovery And Vacuuming Car, China SF6 Gas Recovery And Vacuuming Car manufacturers, suppliers, factory