Knowledge

Solar Module IV Tester

May 28, 2024 Leave a message

solar module IV tester is to use xenon lamp to simulate sunlight for testing, to achieve the power, efficiency, voltage, current and other parameters of the solar cell module test needs. The basic principle of the test system is that when the sun simulates illumination on the solar cell components under test, the electric load is used to control the current change in the solar cell components, and the voltage and current on the volt-ampere characteristic curve of the components are measured.

Performance characteristics

u Irradiance inhomogeneity: Grade A to ensure measurement stability

u Power detection error: < ± 1%, to meet the requirements of small and medium-sized manufacturers

u Quick on-duty operation: on-site training of operators, within 30 minutes can be on duty operation

u Floating frame display: the test software real-time monitoring, when the component measurement parameters do not meet the design requirements, the software automatically prompts alarm, reduce the technical requirements for operators.

 

Product model

HYZG100

PROCESS PARAMETERS

Productivity

<5s/Pcs

Test area

2,000mm*1,000mm

Light source direction

Light source emits light downward

Automation mode

Manual / distribution line

MEASURING PARAMETERS

Light source

HID(High Intensity Discharge Lamp)

Spectrum

--

Light source class

--

Implementation standards

--

Calibration method

--

Spectral match

--

Short-term instability (STI)

--

Long-term instability (LTI)

--

Non-uniformity of irradiance

<2%(Grade A )

Spectral range

400-1100nm

Irradiance time

15ms

Intensity range

1000W / m²

Repetition accuracy

<±1%

Xenon lamp life

Admidia 15W times

Voltage range

0-80V (resolution 1mV)

Current range

0-20A (resolution 1mA)

Solar cell parameter analytics

Isc,Voc,Pmax,Vm,Im,FF,EFF,Temp,Rs,Rsh

PRODUCT DIMENSION AND REQUIREMENTS

System control

Integrated PC runs application software and controls hardware

User interface

Touch screen, keyboard and mouse

Environment

Non-condensing ambient humidity with relative humidity less than 85%

Ambient temperature

25℃± 10℃

Power

AC220V/50Hz/10A

Equipment dimensions

1600mm*2450mm*830mm

Send Inquiry