Products
Capacitive PT Field Calibrator
video
Capacitive PT Field Calibrator

Capacitive PT Field Calibrator

1. There is no need for a booster source, standard transformer, and load box, and the principle of voltage transformer load curve extrapolation is adopted.
2.With polarity, ratio, and wiring check functions.
3 Complete all tests in one connection, improve work efficiency, avoid operation errors, and ensure safety.
Product Introduction

 

When calibrate the error of PT and CVT, the test wire will be complex, required equipment are various and too heavy to move in field. This tester with low voltage can measure the real error under high voltage. Single device can measure the error of PT and CVT.

The measurement of PT and CVT is covered the ratio of 6KV/100V,6KV/ /100V/ ,10KV/100V,10KV/ /100V/,35KV/100V,35V//100V/,110kV/100V,110kV//100V/,220kV/100V and 220kV/ /100V /. It adopts different frequency power technology, general platform technology, Voltage dummy load, internal high accuracy voltage transformer and self - boosting power supply, make it more convenient, quick and efficient. Equipped with WINCE system and colorful touch screen, visual and convenient.

 

Product Parameter

 

Working condition

Temperature

5~40C

Relative humidity

<80%(25C)

Altitude

<4500m

Power frequency

50/0.5Hz

Type of voltage transformer to be measured

GIS electromagnetic (PT),capacitor voltage transformer (CVT)

Error measurement accuracy

0.05%

Accuracy of divider ratio measurement

0.50%

Accuracy of divider capacitance measurement

2%

Accuracy of DC resistance measurement

0-0.1Ω -> 3%,0.1-50Ω -> 1%

Ratio range

6KV/100V

6KV/√3, /100V/√3

10KV/100V

10KV/√3, /100V/√3

35KV/100V

35KV/√3, /100V/√3

110KV/100V

110KV/√3, /100V/√3

2200KV/100V

220KV/√3, /100V/√3

Accuracy level

0.02%

Calibrator verification part

Voltage range

0-100V (error 0.5%)

Ratio difference

0.001%-3% (100V)

Angle difference

0.00′-50′(100V)

Error

▲X=+(2%×X+2%×Yx2d)

Admittance

0.1mS-99.9mS

Error

▲X=+(2%×X+2%×Yx2d),▲Y=?(2%×X+2%×Yx2d)

Dimension (mm)

496*394*185 mm

Weight(Kg)

14

 

Product Feature And Application

 

1. Without a booster, standard instrument transformer, or load case, adopt the principle of load curve extrapolation method for a voltage transformer. a single device can measure the ratio difference and angle difference under the 20%,50%,80%,100%, and 120% full load and light load of GIS, PT, and CVT.

2.  A Single device can measure the error (ratio and angle difference) of PT and CV. Simultaneously measure the capacity voltage dividing ratio, the capacity of voltage dividing, middle PT ratio, middle voltage, current resistance, etc.

3. It has the function of checking polarity, change ratio, and connection.

4. Complete all the tests of wiring at one time, improve the working efficiency, avoid personal and instrument damage caused by operation errors, and ensure safety.

5. Fast test and has a large amount of information processing and large storage capacity (millions of data can be stored), it has 16 G of memory and can store millions of data sets.

6. Adopt variable frequency technology, digital processing, and strong anti-jamming capability.

7. The voltage is not more than 4KV during the test, and various protective measures to ensure personal safety and equipment safety and reliability.

8. Easy to operate.

9. Equipped with the WINCE system, and colorful touch operation, it can be operated by mouse, and the interface is visual and convenient.

10. With double USB communication ports, the internal data of the instrument can be imported into the U disk, which is greatly convenient for field data management. It can be operated by a mouse.

11. With an internal wiring diagram, make it simple and intuitive. By using control wiring on site, the test wiring can be completed correctly in one time and the preparation time can be reduced.

 

Accessory

 

Number

Name

Amount

1

Host

one

2

Quad-core aviation plug with balck shield

one

3

Double-core aviation plug with black shield

one

4

High voltage wire (red)

one

5

High voltage wire (black)

one

6

Transparent ground copper wire

one

7

Power line

one

8

Test clip

four red, four black

9

220V Fuse

three

 

FAQ

 

1. Delivery: Fast delivery and Flexible mode of transportation
2. Payment: Choose payment terms and payment way you convenient
3. Sale service: 24-hour online contact, Choose the right model of equipment according to your request, give the best offer, support customization
4. Warranty period: All machine quality guarantees for one year and lifetime technical support for you. Online response to customers' technical problems.

 

Customer Visit

 

product-1280-720

On Site Service

 

product-1200-600

Packing detail

product-1142-517

Our service

01

Pre-sale service

Conduct product consultation, product promotion, and marketing activities, and technical support for customer needs.

02

Delivery service

Packing with wooden cases, provide different solutions of shipping way, accept different payment way. Save shipping cost and make sure the products arrive well.

03

After-sales service

Installation and commissioning of specific products; Respond to consumer questions, answer consumer inquiries, and deal with consumer comments.

modular-1

Hot Tags: capacitive pt field calibrator, China capacitive pt field calibrator manufacturers, suppliers, factory, CT test equipment, voltage transformer analyzer, CVT tester, CT analyzer, CT VT tansformer testing, burden test of current transformer

Send Inquiry