HYS-60B Electret Electrostatic Generator for Melt-blown Fabric
It can spray static electricity to non-woven fabrics, so that the filtration efficiency of the mask against the streptococcus aureus aerosol with an average particle diameter of (3±0.3) μm is not less than 95%.
Introduction

HYS-60B Electret Electrostatic Generator for Melt-blown Fabric

It can spray static electricity to non-woven fabrics, so that the filtration efficiency of the mask against the streptococcus aureus aerosol with an average particle diameter of (3±0.3) μm is not less than 95%, and plays an indispensable role in mask production line

Features

1、Safe and easy to use.

2、good electrical performance, strong moisture-proof ability, no leakage, good performance and high precision。

3、It can spray static electricity to non-woven fabrics, so that the filtration efficiency of the mask against the streptococcus aureus aerosol with an average particle diameter of (3±0.3) μm is not less than 95%.

4、Using special high voltage power supply, digital control mode, all abnormal slow start, nanosecond arc response ability, to ensure the production line of melting spray without failure, all-day operation.

5、No harm will be caused to the non-woven fabric when the discharge is ignited;The nanosecond arc response ensures that the power supply is quickly restarted within 20ms, resulting in a uniform electrification effect. High- stability can make the ionization effect more stable.

6、It has the advantages of high efficiency, low flow resistance, anti-bacteria, energy saving, etc., which can guarantee the physical collision barrier function of conventional filter materials and increase the electrostatic adsorption.

Parameters

standard

60/2

Rated voltagekV

60

Rated currentmA

2

Rated powerW

120

weightkg

9

volumemm3

465*390*190

HV part heightmm

440

Output voltage accuracy

±(1.0%reading±2d)

Output voltage current accuracy

±(1.0%reading±2d)

Rapple factor

≤0.5%

Working way

Intermittent use, rated load 30 minutes

Overload capacity

No-load voltage may exceed rated voltage by 10% for 10 minutes

The maximum charging current is 1.25 times the rated current

powerAC220V±10% 50Hz

work environment

temperature-10-40℃

Relative humidity: no more than 85% at room temperature of 25℃ (no condensation)

altitudeunder 1500meters

Accessory
RELATED PRODUCTS
  • HYJF-2000 Dual channel digital PD detector
  • HYS-60B Electret Electrostat...
  • FD-III Arrester Discharge Counter Detector
  • RQ-H Automatic Capacitance Bridge Tester
  • CI-HI Automatic Capacitance...
  • CI-H Automatic Capacitance ...
  • RG-H Automatic Capacitance Inductance Tester
  • SC-2000B Portable DC Ground Fault Detector
Inquiry
Your Name:
E-mail:
Phone:
Title:
Content: